Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Dairy Sci ; 107(1): 141-154, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37690728

RESUMEN

Milk proteins can be used as encapsulation walls to increase the bioavailability of active compounds because they can bind hydrophobic, hydrophilic, and charged compounds. The objective of this study was to investigate the effects of astaxanthin (ASTA) encapsulation and the functional properties of milk protein and ASTA nanocomposites by an ultrasound-assisted pH-shifting treatment of different milk proteins, including milk protein concentrate (MPC), micellar casein (MCC), and whey protein isolate (WPI). The ultrasound-assisted pH-shifting treatment of milk protein helped to improve the encapsulation rate of ASTA. Therein, MCC showed great improvement of encapsulating ASTA after co-treatment with the raised encapsulated rate of 5.11%, followed by WPI and MPC. Furthermore, the nanocomposites of ASTA with milk protein exhibit improved bioavailability, antioxidant capacity, and storage stability. By comparison, MCC-encapsulated ASTA has the best storage stability, followed by MPC, and WPI-encapsulated ASTA has the least stability over a 28-d storage period. The results of intrinsic fluorescence and surface hydrophobicity showed that milk protein underwent fluorescence quenching after binding to ASTA, which was due to the hydrophobic sites of the protein being occupied by ASTA. In general, the nanocomposites of milk protein and ASTA fabricated by using an ultrasound-assisted pH-shifting treatment have the potential to be better nano-delivery systems for ASTA in functional foods, especially MCC, which showed excellent performance in encapsulation after treatment technique.


Asunto(s)
Caseínas , Micelas , Animales , Caseínas/química , Proteína de Suero de Leche/química , Proteínas de la Leche/metabolismo , Concentración de Iones de Hidrógeno , Xantófilas
2.
Zhonghua Er Ke Za Zhi ; 61(11): 1024-1030, 2023 Nov 02.
Artículo en Chino | MEDLINE | ID: mdl-37899342

RESUMEN

Objective: To explore the clinical characteristics, common pathogens in children with vulvovaginitis. Methods: This was a retrospective cases study. A total of 3 268 children with vulvovaginitis were enrolled, who visited the Department of Pediatric and Adolescent Gynecology, Children's Hospital, Zhejiang University School of Medicine from January 2009 to December 2019. Patients were divided into 3 groups according to the age of <7, 7-<10 and 10-18 years. Patients were also divided in to 4 groups according to the season of first visit. The pathogen distribution characteristics of infective vulvovaginitis were compared between the groups. Their clinical data were collected and then analyzed by χ2 test. Results: The were 3 268 girls aged (6.2±2.5) years. There were 1 728 cases (52.9%) aged <7 years, 875 cases (26.8%) aged 7-<10 years, and 665 cases (20.3%) aged 10-18 years. Of these cases, 2 253 cases (68.9%) were bacterial vulvovaginitis, 715 cases (21.9%) were fungal vulvovaginitis and 300 cases (9.2%) were vulvovaginitis infected with other pathogens. Bacterial culture of vaginal secretions was performed in 2 287 cases, and 2 287 strains (70.0%) of pathogens were detected, of which the top 5 pathogens were Streptococcus pyogenes (745 strains, 32.6%), Haemophilus influenzae (717 strains, 31.4%), Escherichia coli (292 strains, 12.8%), Staphylococcus aureus (222 strains, 9.7%) and Klebsiella pneumoniae (67 strains, 2.9%). Regarding different age groups, H.influenzae was the most common in children under 7 years of age (40.3%, 509/1 263), S.pyogenes (41.9%, 356/849) was predominantly in children aged 7 to 10 years, and E.coli was predominant in children aged 10 to 18 years (26.3%, 46/175). Susceptibility results showed that S.pyogenes was susceptible to penicillin G (610/610, 100.0%), ceftriaxone (525/525, 100.0%), and vancomycin (610/610, 100.0%); the resistance rates to erythromycin and clindamycin were 91.9% (501/545)and 90.7% (495/546), respectively. For H.influenzae, 32.5% (161/496) produced ß-elactamase, and all strains were sensitive to meropenem (489/489, 100.0%) and levofloxacin (388/388, 100.0%), while 40.5% (202/499) were resistant to ampicillin. Among E.coli, all strains were sensitive to imipenem(100%, 175/175). The resistance rates of E.coli to levofloxacin and ceftriaxone were 29.1% (43/148) and 35.1% (59/168), respectively. A total of 48 strains of methicillin-resistant Staphylococcus aureus (MRSA) were isolated with a proportion of 28.3% (45/159) in 3 268 patients. The results of drug susceptibility test showed that all MRSA strains were sensitive to linezolid 100.0% (40/40), vancomycin (45/45, 100.0%), and tigecycline (36/36, 100.0%); the resistance rates of MRSA to penicillin G, erythromycin and clindamycin were 100% (45/45), 95.6% (43/45) and 88.9% (40/45), respectively. All methicillin-sensitive Staphylococcus aureus (MSSA) strains were sensitive to oxacillin (114/114, 100.0%), linezolid (94/94, 100.0%), vancomycin (114/114, 100.0%), and tigecycline (84/84, 100.0%); it's resistance rates to penicillin G, erythromycin and clindamycin were 78.1% (89/114), 59.7% (68/114) and 46.5% (53/114), respectively. The drug resistance rate of MSSA to penicillin G, erythromycin and clindamycin were lower than those of MRSA (χ²=11.71,19.74,23.95, respectively, all P<0.001). Conclusions: The age of consultation for pediatric infectious vulvovaginitis is mainly around 6 years. The most common pathogens are S.pyogenes, H.influenzae and Escherichia coli. Third generation cephalosporins can be used as the first choice of empirical anti-infection drugs. However, the results of drug susceptibility should be considered for targeted treatment.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina , Infecciones Estafilocócicas , Femenino , Adolescente , Niño , Humanos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Vancomicina/uso terapéutico , Clindamicina/uso terapéutico , Ceftriaxona/uso terapéutico , Tigeciclina/uso terapéutico , Linezolid/uso terapéutico , Levofloxacino/uso terapéutico , Estudios Retrospectivos , Pruebas de Sensibilidad Microbiana , Staphylococcus aureus , Infecciones Estafilocócicas/tratamiento farmacológico , Eritromicina/uso terapéutico , Meticilina , Penicilina G/uso terapéutico , Escherichia coli , Farmacorresistencia Bacteriana
3.
Zhonghua Xin Xue Guan Bing Za Zhi ; 50(12): 1214-1219, 2022 Dec 24.
Artículo en Chino | MEDLINE | ID: mdl-36517443

RESUMEN

Objective: To analyze the feasibility and safety of bridge therapy with active fixed electrodes connected to external permanent pacemakers (AFLEP) for patients with infective endocarditis after lead removal and before permanent pacemaker implantation. Methods: A total of 44 pacemaker-dependent patients, who underwent lead removal due to infective endocarditis in our center from January 2015 to January 2020, were included. According to AFLEP or temporary pacemaker option during the transition period, patients were divided into AFLEP group or temporary pacemaker group. Information including age, sex, comorbidities, indications and types of cardial implantable electionic device (CIED) implantation, lead age, duration of temporary pacemaker or AFLEP use, and perioperative complications were collected through Haitai Medical Record System. The incidence of pacemaker perception, abnormal pacing function, lead perforation, lead dislocation, lead vegetation, cardiac tamponade, pulmonary embolism, death and newly infection of implanted pacemaker were compared between the two groups. Pneumothorax, hematoma and the incidence of deep vein thrombosis were also analyzed. Results: Among the 44 patients, 24 were in the AFLEP group and 20 in the temporary pacemaker group. Age was younger in the AFLEP group than in the temporary pacemaker group (57.5(45.5, 66.0) years vs. 67.0(57.3, 71.8) years, P=0.023). Male, prevalence of hypertension, diabetes mellitus, chronic renal dysfunction and old myocardial infarction were similar between the two groups (all P>0.05). Lead duration was 11.0(8.0,13.0) years in the AFLEP group and 8.5(7.0,13.0) years in the temporary pacemaker group(P=0.292). Lead vegetation diameter was (8.2±2.4)mm in the AFLEP group and (9.1±3.0)mm in the temporary pacemaker group. Lead removal was successful in all patients. The follow-up time in the AFLEP group was 23.0(20.5, 25.5) months, and the temporary pacemaker group was 17.0(14.5, 18.5) months. In the temporary pacemaker group, there were 2 cases (10.0%) of lead dislocation, 2 cases (10.0%) of sensory dysfunction, 2 cases (10.0%) of pacing dysfunction, and 2 cases (10.0%) of death. In the AFLEP group, there were 2 cases of abnormal pacing function, which improved after adjusting the output voltage of the pacemaker, there was no lead dislocation, abnormal perception and death. Femoral vein access was used in 8 patients (40.0%) in the temporary pacemaker group, and 4 patients developed lower extremity deep venous thrombosis. There was no deep venous thrombosis in the AFLEP group. The transition treatment time was significantly longer in the AFLEP group than in the temporary pacemaker group (19.5(16.0, 25.8) days vs. 14.0(12.0, 16.8) days, P=0.001). During the follow-up period, there were no reinfections with newly implanted pacemakers in the AFLEP group, and reinfection occurred in 2 patients (10.0%) in the temporary pacemaker group. Conclusions: Bridge therapy with AFLEP for patients with infective endocarditis after lead removal and before permanent pacemaker implantation is feasible and safe. Compared with temporary pacemaker, AFLEP is safer in the implantation process and more stable with lower lead dislocation rate, less sensory and pacing dysfunction.


Asunto(s)
Endocarditis Bacteriana , Marcapaso Artificial , Humanos , Masculino , Terapia Puente , Estudios de Factibilidad , Endocarditis Bacteriana/etiología , Electrodos , Remoción de Dispositivos
4.
Zhonghua Xin Xue Guan Bing Za Zhi ; 50(11): 1069-1073, 2022 Nov 24.
Artículo en Chino | MEDLINE | ID: mdl-36418274

RESUMEN

Objective: For patients with paroxysmal atrial fibrillation, superior vena cava isolation on the basis of pulmonary vein isolation may further improve the long-term success rate of radiofrequency ablation. We aimed to explore the efficacy and safety of superior vena cava isolation by high-power and short-duration (HPSD) ablation plus conventional radiofrequency ablation (RA) in patients with paroxysmal atrial fibrillation. Methods: It was a prospective randomized controlled study. From January 1, 2019 to June 1, 2020, 180 patients who underwent radiofrequency ablation for paroxysmal atrial fibrillation in our center were consecutively screened. Patients were eligible if there was a trigger potential and the muscle sleeve length was greater than 3 cm. A total of 60 eligible patients were finally included and randomly divided into HPSD group (HPSD plus RA) and common power and duration (CPD) group (CPD plus RA) by random number table method (n=30 in each group). Efficacy was evaluated by ablation points, isolation time and ablation time. Safety was evaluated by the incidence of POP, cardiac tamponade, phrenic nerve injury, sinoatrial node injury and all-cause. Results: Superior vena cava isolation was achieved by 14 (13, 15) points in the HPSD group, which was significantly less than that in the CPD group (20(18, 22), P<0.001). The superior vena cava isolation time was 8 (7, 9) minutes in the HPSD group, which was significantly shorter than in the CPD group (17(14, 20) minutes, P<0.001). The average ablation time significantly shorter in HPSD group than in CPD group (78.0(71.1, 80.0) s vs. 200(167.5, 212.5)s, P<0.001). The average impedance drop was more significant in the HPSD group than in the CPD group (20.00(18.75, 21.00)Ω (and the percentage of impedance drop was 15%) vs. 12.00(11.75, 13.25)Ω (the percentage of impedance decrease was 12%), P<0.001). There was 1 POP (3.3%) in the HPSD group, and 3 POPs (10.0%) in the CPD group (P>0.05). There was no cardiac tamponade, phrenic nerve injury, sinoatrial node injury and death in both groups. Conclusions: HPSD technique for the isolation of superior vena cava is safe and effective in patients with paroxysmal atrial fibrillation undergoing conventional radiofrequency ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Radiofrecuencia , Humanos , Fibrilación Atrial/cirugía , Vena Cava Superior/cirugía , Estudios Prospectivos , Resultado del Tratamiento
5.
Zhonghua Xin Xue Guan Bing Za Zhi ; 50(8): 799-804, 2022 Aug 24.
Artículo en Chino | MEDLINE | ID: mdl-35982013

RESUMEN

Objective: To evaluate the effect of Li's catheter in cardiac resynchronization therapy (CRT) implantation. Methods: This study was a retrospective cohort study. Patients with indications for CRT implantation who visited the Department of Cardiology, Peking University People's Hospital from January 1, 2016 to January 1, 2022 were enrolled. Patients were divided into Li's catheter group (CRT implantation with Li's catheter) and control group (CRT implantation with the traditional method). The general clinical data of the patients were obtained through the electronic medical record system. Li's catheter is a new type of coronary sinus angiography balloon catheter independently developed by Dr. Li Xuebin (patent number: 201320413174.1). The primary outcome was the success rate of CRT device implantation, and the secondary outcomes included efficacy and safety parameters. Efficacy indicators included operation time, coronary sinus angiography time, left ventricular lead implantation time, X-ray exposure time, left ventricular lead threshold, and diaphragm stimulation. Safety outcomes included incidence of coronary sinus dissection, cardiac tamponade, and pericardial effusion. Results: A total of 170 patients were enrolled in this study, including 90 in Li's catheter group and 80 in control group. Age, male proportion of patients, proportion of patients with ischemic cardiomyopathy, hypertension, diabetes mellitus, chronic renal insufficiency, New York Heart Association (NYHA) functional classification, left ventricular ejection fraction, left ventricular end-diastolic diameter, proportion of left bundle branch block, and preoperative QRS wave width were similar between the two groups (all P>0.05). In Li's catheter group, 34 cases (37.8%) implanted with CRT defibrillators, and 28 cases (35.0%) implanted with CRT defibrillators in control group, the difference was not statistically significant (P=0.710). The success rate of CRT device implantation in Li's catheter group was 100% (90/90), which was significantly higher than that in control group (93.8%, 75/80, P=0.023).The operation time was 57.0 (52.0, 62.3) minutes, the time to complete coronary sinus angiography was 8.0 (6.0, 9.0) minutes, and the time of left ventricular electrode implantation was 8.0 (7.0, 9.0) minutes in Li's catheter group, and was 91.3 (86.3, 97.0), 18.0 (16.0, 20.0), 25.0 (22.0, 27.7) minutes respectively in control group, all significantly shorter in Li's catheter group (all P<0.05). The exposure time of X-ray was 15.0 (14.0, 17.0) minutes in Li's catheter group, which was also significantly shorter than that in control group (32.5 (29.0, 36.0) minutes, P<0.001). There was no coronary sinus dissection and cardiac tamponade in Li's catheter group, and 1 patient (1.1%) had diaphragmatic stimulation in Li's catheter group. In control group, 6 patients (6.7%) had coronary sinus dissection, and 1 patient (1.1%) developed pericardial effusion, and 3 patients (3.3%) had diaphragmatic stimulation. The incidence of coronary sinus dissection in Li's catheter group was significantly lower than that in control group (P=0.011). The postoperative left ventricular thresholds in Li's catheter group and control group were similar (1.80 (1.60, 2.38) V/0.5 ms vs. 1.80 (1.60, 2.40) V/0.5 ms, P=0.120). Conclusions: Use of Li's catheter is associated with higher success rate of CRT implantation, short time of coronary sinus angiography and left ventricular electrode implantation, reduction of intraoperative X-ray exposure, and lower incidence of coronary vein dissection in this patient cohort.


Asunto(s)
Terapia de Resincronización Cardíaca , Taponamiento Cardíaco , Insuficiencia Cardíaca , Derrame Pericárdico , Terapia de Resincronización Cardíaca/métodos , Taponamiento Cardíaco/terapia , Catéteres , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Phys Rev Lett ; 122(8): 082001, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30932568

RESUMEN

We present the first measurements of absolute branching fractions of Ξ_{c}^{0} decays into Ξ^{-}π^{+}, ΛK^{-}π^{+}, and pK^{-}K^{-}π^{+} final states. The measurements are made using a dataset comprising (772±11)×10^{6} BB[over ¯] pairs collected at the ϒ(4S) resonance with the Belle detector at the KEKB e^{+}e^{-} collider. We first measure the absolute branching fraction for B^{-}→Λ[over ¯]_{c}^{-}Ξ_{c}^{0} using a missing-mass technique; the result is B(B^{-}→Λ[over ¯]_{c}^{-}Ξ_{c}^{0})=(9.51±2.10±0.88)×10^{-4}. We subsequently measure the product branching fractions B(B^{-}→Λ[over ¯]_{c}^{-}Ξ_{c}^{0})B(Ξ_{c}^{0}→Ξ^{-}π^{+}), B(B^{-}→Λ[over ¯]_{c}^{-}Ξ_{c}^{0})B(Ξ_{c}^{0}→ΛK^{-}π^{+}), and B(B^{-}→Λ[over ¯]_{c}^{-}Ξ_{c}^{0})B(Ξ_{c}^{0}→pK^{-}K^{-}π^{+}) with improved precision. Dividing these product branching fractions by the result for B^{-}→Λ[over ¯]_{c}^{-}Ξ_{c}^{0} yields the following branching fractions: B(Ξ_{c}^{0}→Ξ^{-}π^{+})=(1.80±0.50±0.14)%, B(Ξ_{c}^{0}→ΛK^{-}π^{+})=(1.17±0.37±0.09)%, and B(Ξ_{c}^{0}→pK^{-}K^{-}π^{+})=(0.58±0.23±0.05)%. For the above branching fractions, the first uncertainties are statistical and the second are systematic. Our result for B(Ξ_{c}^{0}→Ξ^{-}π^{+}) can be combined with Ξ_{c}^{0} branching fractions measured relative to Ξ_{c}^{0}→Ξ^{-}π^{+} to yield other absolute Ξ_{c}^{0} branching fractions.

8.
Phys Rev Lett ; 113(14): 142001, 2014 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-25325633

RESUMEN

The e(+)e(-) → π(+)π(-)π(0)χ(bJ) (J = 0,1,2) processes are studied using a 118 fb(-1) data sample acquired with the Belle detector at a center-of-mass energy of 10.867 GeV. Unambiguous π(+)π(-)π(0)χ(bJ) (J = 1,2), ωχ(b1) signals are observed, and indication for ωχ(b2) is seen, both for the first time, and the corresponding cross section measurements are presented. No significant π(+)π(-)π(0)χ(b0) or ωχ(b0) signals are observed, and 90% confidence level upper limits on the cross sections for these two processes are obtained. In the π(+)π(-)π(0) invariant mass spectrum, significant non-ω signals are also observed. We search for the X(3872)-like state (named X(b)) decaying into ωϒ(1S); no significant signal is observed with a mass between 10.55 and 10.65 GeV/c(2).

9.
Phys Rev Lett ; 110(25): 252002, 2013 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-23829730

RESUMEN

The cross section for ee+ e- → π+ π- J/ψ between 3.8 and 5.5 GeV is measured with a 967 fb(-1) data sample collected by the Belle detector at or near the Υ(nS) (n = 1,2,…,5) resonances. The Y(4260) state is observed, and its resonance parameters are determined. In addition, an excess of π+ π- J/ψ production around 4 GeV is observed. This feature can be described by a Breit-Wigner parametrization with properties that are consistent with the Y(4008) state that was previously reported by Belle. In a study of Y(4260) → π+ π- J/ψ decays, a structure is observed in the M(π(±)J/ψ) mass spectrum with 5.2σ significance, with mass M = (3894.5 ± 6.6 ± 4.5) MeV/c2 and width Γ = (63 ± 24 ± 26) MeV/c2, where the errors are statistical and systematic, respectively. This structure can be interpreted as a new charged charmoniumlike state.

10.
Phys Rev Lett ; 108(23): 232001, 2012 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-23003948

RESUMEN

The processes γγ → ωϕ, ϕϕ, and ωω are measured using an 870 fb(-1) data sample collected with the Belle detector at the KEKB asymmetric-energy e+ e- collider. Production of vector meson pairs is clearly observed and their cross sections are measured for masses that range from threshold to 4.0 GeV. In addition to signals from well established spin-zero and spin-two charmonium states, there are resonant structures below charmonium threshold, which have not been previously observed. We report a spin-parity analysis for the new structures and determine the products of the η(c), χ(c0), and χ(c2) two-photon decay widths and branching fractions to ωϕ, ϕϕ, and ωω.

11.
Nanoscale ; 3(2): 529-45, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21063631

RESUMEN

This feature article provides an overview of the recent research progress on the hierarchically structured carbon-based composites for electrochemical capacitors. The basic principles of electrochemical capacitors, and the design, construction and performance of hierarchically structured carbon-based composites electrode materials with good ions and electron transportation and large specific surface area are discussed. The trend of future development of high-power and large-energy electrochemical capacitors is proposed.


Asunto(s)
Nanotubos de Carbono/química , Técnicas Electroquímicas , Grafito/química , Óxidos/química , Porosidad , Rutenio/química , Termodinámica
12.
Phys Rev Lett ; 104(11): 112004, 2010 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-20366468

RESUMEN

The process gammagamma-->phiJ/psi is measured using a data sample of 825 fb{-1} collected with the Belle detector. A narrow peak of 8.8{-3.2}{+4.2} events, with a significance of 3.2 standard deviations including systematic uncertainty, is observed. The mass and natural width of the structure [named X(4350)] are measured to be [4350.6{-5.1}{+4.6}(stat)+/-0.7(syst)] MeV/c{2} and [13{-9}{+18}(stat)+/-4(syst)] MeV, respectively. The product of its two-photon decay width and branching fraction to phiJ/psi is [6.7{-2.4}{+3.2}(stat)+/-1.1(syst)] eV for J{P}=0{+}, or [1.5{-0.6}{+0.7}(stat)+/-0.3(syst)] eV for J{P}=2{+}. No signal for the Y(4140)-->phiJ/psi structure reported by the CDF Collaboration in B-->K{+}phiJ/psi decays is observed, and limits of Gamma_{gammagamma}(Y(4140))B(Y(4140)-->phiJ/psi)<41 eV for J{P}=0;{+} or <6.0 eV for J{P}=2{+} are determined at the 90% C.L. This disfavors the scenario in which the Y(4140) is a D{s}{*+}D{s}{*-} molecule.

13.
Phys Rev Lett ; 99(18): 182004, 2007 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-17995399

RESUMEN

The cross section for e(+)e(-)-->pi(+)pi(-)J/psi between 3.8 and 5.5 GeV/c(2) is measured using a 548 fb(-1) data sample collected on or near the Upsilon(4S) resonance with the Belle detector at KEKB. A peak near 4.25 GeV/c(2), corresponding to the so called Y(4260), is observed. In addition, there is another cluster of events at around 4.05 GeV/c(2). A fit using two interfering Breit-Wigner shapes describes the data better than one that uses only the Y(4260), especially for the lower-mass side of the 4.25 GeV enhancement.

14.
Phys Rev Lett ; 99(14): 142002, 2007 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-17930661

RESUMEN

The cross section for e+ e- --> pi+ pi- psi(2S) between threshold and sqrt[s]=5.5 GeV is measured using 673 fb(-1) of data on and off the Upsilon(4S) resonance collected with the Belle detector at KEKB. Two resonant structures are observed in the pi+ pi- psi(2S) invariant-mass distribution, one at 4361 +/- 9 +/- 9 MeV/c2 with a width of 74 +/- 15 +/- 10 MeV/c2, and another at 4664 +/- 11 +/- 5 MeV/c2 with a width of 48 +/- 15 +/- 3 MeV/c2, if the mass spectrum is parametrized with the coherent sum of two Breit-Wigner functions. These values do not match those of any of the known charmonium states.

15.
Anim Genet ; 38(3): 203-10, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17539972

RESUMEN

Two sequence variants of the aldolase C (ALDOC) gene were discovered based on comparison of the sequences from an altiplano chicken breed (Tibetan chicken) and two lowland breeds (White Leghorn and ShouGuang). Gel-shift results indicated that one of these variants, L25375:c.310-258G>A, was able to bind hypoxia-induced factor-l (HIF1A), therefore, functioning as a hypoxia response element (HRE). The combined activity of the HRE and HIF1A could increase under the influence of a hypoxic stimulus. Hypoxia leads to increased death rates of chicken embryos, while the L25375:c.310-258G>A described herein is prevalent in healthy embryos grown under hypoxic conditions. Fluorescence quantitative real-time PCR results revealed that HIF1A upregulated the transcript level of the glycolytic enzyme ALDOC in the brain and skeletal muscle of animals subjected to hypoxia. Thus, a large amount of ATP is produced by increased glycolysis, allowing the organism to meet energy metabolism demands. As such, we believe this sequence variant is an adaptation to external anoxic environment.


Asunto(s)
Adaptación Fisiológica/genética , Pollos/genética , Fructosa-Bifosfato Aldolasa/metabolismo , Regulación de la Expresión Génica/genética , Factor 1 Inducible por Hipoxia/metabolismo , Hipoxia/metabolismo , Animales , Secuencia de Bases , Encéfalo/metabolismo , Cartilla de ADN , Ensayo de Cambio de Movilidad Electroforética , Fructosa-Bifosfato Aldolasa/genética , Datos de Secuencia Molecular , Músculo Esquelético/metabolismo , Oligonucleótidos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Análisis de Secuencia de ADN
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...